| Tank
overflow 'D' is to prevent liquid level rising in pump body and damaging the motor.
The lower lip of overflows 'D' should not to move than 1/2" above center
of pump overflow. Isolation valve for scaling the tank during maintenance not
essential for efficient working of the pump. | |
A
vertical suction pipe with non-return valve with entering top of tank may be used
when liquid is free from suspended solids |
|
INSTALLATION 1
-
Fully open valve 'A'
- Allow
level of liquid to rise in supply tank up to overflow 'D' level
-
Close valve 'B'
-
Start pump
- Open
valve 'B' gradually for required flow
| |
INSTALLATION 2
- Close
valves 'A' and 'B'
- Open
valve 'D' and leave running until liquid flows out of 'C'
-
Start pump and immediately open valve 'A' fully
-
Close valve 'D'
- Open
valve 'B' gradually for required flow.
|
| | |
 | |  |
| | Valve
'A' must be at least 1/2 size large in bore then suction pipe |
| INSTALLATION
3 - Close
valves 'A' and 'B'
- Open
valve 'D'
- Fill
priming vessel to overflow 'C'
- Start
pump
- Open
valves 'A'
-
Close valve 'D' and open valve 'B' for flow required
| |
INSTALLATION
4 - Close
valve 'A' and 'B'
- Fill
priming vessel
- Start
pump
- Open
valve 'A' gradually until fully open
- Open
valve 'B' gradually for required flow
|
| | |
 | |
INSTALLATION
& OPERATION
Where Low Level priming is not required
Where Low Level priming is required.
Where priming at all levels is required.
Where priming at all levels is required without re-circulation.
For deep variable head storage tanks or where suction lifts must be hopt to minimum.
All
installation must have the overflow from the pump to the supply or priming vessel:- - Straight
- Have
no restriction (valves etc.)
- Stop
down -1 in 20 or more
- Preferably
12" long maximum
- Valves
'A' to be of the free flow type.
|
| INSTALLATION
5 This
installation is basically scheme 1 but level in supply tank is regulated by a
mechanical or electrical flow control valve. Installation for deep variable
head storage tanks, or where suction lifts must be kept to a minimum.
| |
| | |
| | |